GATE Mechanical Engineering (ME) 2012 Solved Paper

Show Para  Hide Para 
Question Numbers: 60-61
A refrigerator operates between 120 kPa and 800 kPa in an ideal vapour compression cycle with R-134a as the refrigerant. The refrigerant enters the compressor as saturated vapour and leaves the condenser as saturated liquid The mass flow rate of the refrigerant is 0.2 kg/s. Properties for R – 134a are as follows
Saturated R – 134a
P(kPa)
T°C
hf (kJ/kg)
hg (kJ/ kg)
Sf (kJ / kg.k)
Sg(kJ /kg.k)
120
-22.32
22.5
237
0.093
0.95
800
31.31
95.5
267.3
0.354
0.918
 
Superheated R – 134a
P(kPa)
T°C
h (kJ/ kg)
S (kJ / kg.k)
800
40
276.45
0.95
© examsnet.com