Direction of rotation of a DC shunt motor is reversed by either reversing armature connector or reversed field connection because torque produce by DC shunt motor T∝Iaϕ . if reversed either of armature connection or field connection, torque will reverse in rotation. if we reversed both armature connection and field connection then direction of rotation is in same direction as Previous.